کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2662369 1403712 2016 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Transparent Film Intravenous Line Dressing Incorporating a Chlorhexidine Gluconate Gel Pad: A Clinical Staff Evaluation
ترجمه فارسی عنوان
دکوراسیون شفاف خط داخل وریدی فیلم با ترکیب ژل پد گلوکونات کلرهگزیدین: یک ارزیابی کارکنان بالینی
کلمات کلیدی
CHG؛ مراقبت‌های ویژه؛ CVC؛ پانسمان IV؛ vascath
موضوعات مرتبط
علوم پزشکی و سلامت پرستاری و مشاغل بهداشتی پرستاری
چکیده انگلیسی


• Clinical staff were satisfied with the IV dressing incorporating a CHG gel pad.
• An IV dressing incorporating a CHG gel pad performed well in a diverse group of critical care patients.
• The number of dressing changes did not differ significantly between the catheter insertion sites.

BackgroundChlorhexidine gluconate (CHG) has been shown to reduce the microbial load at intravascular (IV) catheter insertion sites and the risk of catheter-related infections. The Centers for Disease Control and Prevention and the UK National Institute for Health and Care Excellence subsequently recommended CHG-containing IV dressings for specific clinical indications.AimTo evaluate clinical staff perceptions of a standard transparent IV dressing in comparison to a transparent IV dressing incorporating a 2% (w/w) CHG gel pad when used at the insertion site of short-term central venous catheters and vascular access catheters for dialysis in adult critical care patients.MethodsFollowing a 9-month trial period during which a CHG dressing was introduced to critical care patients at a university hospital, the staff perception of this dressing in comparison to a standard transparent IV dressing was evaluated by a questionnaire. The number of dressing changes required and skin condition under the dressing was also determined in a proportion of patients.ResultsThe majority of the clinical staff (70 out of 81 respondents) considered the performance of the IV dressing containing a CHG gel pad better or much better than the standard dressing, and 77 out of 78 of the respondents recommended continuing its use. Both types of dressing performed well when applied to the insertion site of IV catheters in the internal jugular, subclavian, or femoral vein.ConclusionsStaff satisfaction with the IV dressing incorporating a CHG gel pad was rated good, and the dressing performed well in a diverse group of critical care patients.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of the Association for Vascular Access - Volume 21, Issue 3, September 2016, Pages 133–138
نویسندگان
, , , , , ,