کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
294916 511501 2016 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Improvement of image characteristics in high-voltage computed tomography (CT) by applying a compressed-sensing (CS)-based image deblurring scheme
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی عمران و سازه
پیش نمایش صفحه اول مقاله
Improvement of image characteristics in high-voltage computed tomography (CT) by applying a compressed-sensing (CS)-based image deblurring scheme
چکیده انگلیسی

We have established a high-voltage computed tomography (CT) system with a 1–3 MV LINAC x-ray generator for industrial nondestructive testing. However, reconstructed CT images are typically blurred, limiting its image performance, mainly due to the finite focal spot size of the x-ray source, aspects inherent to detector such as the detector pixel size and the detector resolution, and the reconstruction procedure as well. Thus the recovery of the reconstructed CT images from their degraded version is essential for improving the image characteristics. In this work, we investigated the compressed-sensing (CS)-based deconvolution scheme for more accurate image deblurring in CT. We implemented the proposed image deblurring algorithm for CT and performed a systematic simulation and experiment to demonstrate its viability. Our results indicate that the proposed deblurring scheme appears to be effective for the blurring problems in CT and is applicable to improve its present image characteristics.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: NDT & E International - Volume 84, December 2016, Pages 11–19