کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3159585 1198345 2014 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
An analysis of failure of 5-year loaded tapered implants with SLA surface
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی دندانپزشکی، جراحی دهان و پزشکی
پیش نمایش صفحه اول مقاله
An analysis of failure of 5-year loaded tapered implants with SLA surface
چکیده انگلیسی
The purpose of this study was to analyze the risk factors for 5-year loaded tapered implants with SLA surface. From June 2003 to February 2005, 65 patients (a total of 139 Implantium® (Dentium, Suwon, Korea) implants) were enrolled and cumulative survival was calculated based on Kaplan-Meier method. To confirm prognosis factors, Cox proportional hazard model was established. Among the 139 implants, 6 implants failed and the 5-year cumulative survival rate was 95.41%. Failed implants were 3 for osseointegration failure, 1 for malposition, and 2 for peri-implantitis and progressive bone loss respectively. There were no meaningful differences in the cumulative survival rates between maxilla and mandible, maxillary posterior area and other regions, and maxillary posterior area with and without sinus bone graft (p > 0.05). Irrespective of graft location, delayed loaded cases due to improper primary stability from simultaneous bone graft increased the failure rate.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Oral and Maxillofacial Surgery, Medicine, and Pathology - Volume 26, Issue 1, January 2014, Pages 7-10
نویسندگان
, , , ,