کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4418989 1618929 2017 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Determination of As, Cr, Mo, Sb, Se and V in agricultural soil samples by inductively coupled plasma optical emission spectrometry after simple and rapid solvent extraction using choline chloride-oxalic acid deep eutectic solvent
ترجمه فارسی عنوان
تعیین As، کروم، مولیبدن، SB، Se و V در نمونه های خاک کشاورزی با طیف سنجی انتشار نوری پلاسمای همراه پس از استخراج حلال ساده و سریع با استفاده از حلال یوتکتیک عمیق اسید کولین کلراید ـ اگزالیک
کلمات کلیدی
موضوعات مرتبط
علوم زیستی و بیوفناوری علوم محیط زیست شیمی زیست محیطی
چکیده انگلیسی


• Choline chloride–oxalic acid DES was used for extraction of trace metals from soils.
• The extracted trace elements were quantified by ICP-OES.
• Optimal experimental conditions were determined by full factorial design.
• The extraction efficiency of the develop method was satisfactory.

A rapid, simple and green ultrasound-assisted extraction method using deep eutectic solvents (DES) for extraction of As, Cr, Mo, Sb, Se and V in soil samples, has been developed. Choline chloride–oxalic acid based DES was used as a solvent. The target analytes were subsequently quantified using inductively coupled plasma optical emission spectrometer (ICP OES). The parameters that affect the extraction of the target analytes was optimized using standard reference material of San Joaquin soil (SRM 2709a). In the optimization step, a two-level full factorial experimental design was used. The factors under investigation include extraction time, sample mass and acid concentration. Under optimized conditions, limits of detection (LOD) and limits of quantification (LOQ) ranged from 0.009 to 0.1 and 0.03–0.3 µg g−1, respectively. The repeatability (n=20) estimated in terms of relative standard deviation (%RSD) ranged from 0.9% to 3.7%. The accuracy of the proposed method was carried out using SRM 2709a. The obtained and certified/ indicative values were statistically in good agreement at 95% confidence level. The proposed method applied for quantification of As, Cr, Mo, Sb, Se and V in real soil samples. For comparison, the analytes of interest were also determined using a conventional acid digestion method. According to the paired t-test, the analytical results were not significant differences at 95% confidence level. The method was found to be accurate, precise and environmentally friendly.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Ecotoxicology and Environmental Safety - Volume 135, January 2017, Pages 152–157
نویسندگان
, , ,