کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5006680 1461483 2017 27 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
A drag force anemometer using finite length cylinder with direction measurement capability
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی کنترل و سیستم های مهندسی
پیش نمایش صفحه اول مقاله
A drag force anemometer using finite length cylinder with direction measurement capability
چکیده انگلیسی
This study proposes a new design idea to measure wind speed and direction using drag force. For this aim, load cells which are get aligned with the geographical directions were used. A prototype was built and tested in a wind tunnel located at WEAR Laboratory in Erciyes University. The tests were performed for the direction of 225° between 5 m/s and 25.2 m/s and the outputs were compared with reference velocities. The results were shown that the mean measurement errors of the new design were less than 3% and the mean direction errors were less than 3° respectively, which provided WMO accuracy requirements.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Measurement - Volume 104, July 2017, Pages 117-122
نویسندگان
, , ,