کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5029442 1470666 2016 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
A Novel Method for Uniaxial HCF Testing of Austenitic Stainless Steels
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی (عمومی)
پیش نمایش صفحه اول مقاله
A Novel Method for Uniaxial HCF Testing of Austenitic Stainless Steels
چکیده انگلیسی

Fatigue endurance testing of nuclear plant materials is typically carried out using uniaxial specimens tested under strain control using a triangular waveform and a defined strain rate. This leads to long test durations and high testing costs when testing in the High Cycle Fatigue (HCF) regime, meaning few results for fatigue lives above 106 cycles are available. A novel test method is proposed here, in which the traditional strain-controlled test method is used until 105 cycles have elapsed, before testing is switched to load control at a higher frequency. Testing of a Type 304LN austenitic stainless steel in room temperature air was performed at an R ratio of -1, strain rate of 0.4%/s and strain amplitude of 0.18%. The results show no statistically significant difference between the HCF lives gained from the traditional and new test methods. The proposed new fatigue endurance test method is considered to be validated for use in the testing of nuclear grades of unstabilised austenitic stainless steel in air at room temperature.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Procedia Engineering - Volume 160, 2016, Pages 285-291
نویسندگان
, , , , , ,