کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5032823 1471135 2017 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Modification of the Grood and Suntay Joint Coordinate System equations for knee joint flexion
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی پزشکی
پیش نمایش صفحه اول مقاله
Modification of the Grood and Suntay Joint Coordinate System equations for knee joint flexion
چکیده انگلیسی


- Joint Coordinate System equations require corrections to ensure correct angles are calculated.
- Flexion angle equations can be corrected by using a new tan function.
- This will ensure the entire clinical range of motion has been considered.

Since its introduction, the Grood and Suntay Joint Coordinate System (JCS) has been embraced by the International Society of Biomechanics (ISB) and been widely used for biomechanical reporting. There is, however, a limitation in its ability to provide correct flexion values over a wide range of clinically relevant flexion angles. This technical note addresses the limitation of the JCS equations and introduces a new set of equations to overcome this problem.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Medical Engineering & Physics - Volume 39, January 2017, Pages 113-116
نویسندگان
, ,