کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5136322 1494007 2017 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Development of a derivatization method for the quantification of hydrogen sulfide and its application in vascular calcification rats
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Development of a derivatization method for the quantification of hydrogen sulfide and its application in vascular calcification rats
چکیده انگلیسی


- A reliable and sensitive HPLC method for the determination of H2S was reported.
- The method is sensitive enough to be applied in plasma and various tissues.
- The derivatization reaction for H2S by the isomers (MMB and MBB) was first compared.
- The proposed method has been applicable for studies in the VC model of rats.
- It might be an useful tool for the investigation on the pathological of H2S.

Hydrogen sulfide (H2S) plays major functional and structural roles in diverse physiological functions and the pathogenesis of a variety of disorders in biological matrices. The significance of H2S has prompted the development of sensitive and selective methods to determine its concentration in biological samples. The fluorescent reagent monobromobimane (MBB) has been widely used to measure various thiol-containing species through alkylation. MBB may prevent the oxidation of sulfide and the reaction of sulfide with several different species (such as superoxide radicals, hydrogen peroxide and peroxynitrite). An isomers of MBB, 3-(bromomethyl)-2, 6, 7-trimethyl-1H, 5H-pyrazolo [1,2-a] pyrazole-1, 5-dione (MMB), is cheaper than MBB and its use in the analysis of H2S has not previously been reported. In the present study, we compared the derivatization reactions of hydrogen sulfide with MMB and MBB and developed a sensitive method to quantify H2S in blood. In our method, H2S was incubated in the dark with excess MMB in 0.1 M Tris-HCl buffer (pH 10.1) at 50 °C for 120 min. 50 μL aliquots of the derivatized product were analyzed using HPLC system with gradient elution of 0.1% (v/v) formic acid-acetonitrile. The limit of detection for the derivatized product was 0.03 nmol/mL. The derivatization reaction was suitable for detecting low concentrations of H2S. The derivate product is stable over time, permitting batch storage and analysis.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography B - Volumes 1055–1056, 15 June 2017, Pages 8-14
نویسندگان
, , , , , , ,