کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5545609 1555633 2017 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Evaluation of the PrioCHECK™ Trichinella AAD Kit for the digestion and recovery of larvae in pork, horse meat and wild meat
موضوعات مرتبط
علوم زیستی و بیوفناوری علوم کشاورزی و بیولوژیک علوم دامی و جانورشناسی
پیش نمایش صفحه اول مقاله
Evaluation of the PrioCHECK™ Trichinella AAD Kit for the digestion and recovery of larvae in pork, horse meat and wild meat
چکیده انگلیسی


- PrioCHECK™ AAD Kit is a new digestion assay for Trichinella detection.
- Digestion of pork, horsemeat and wildlife muscle was rapid and complete.
- Larvae recovery rates were similar to those for the pepsin/HCl method when adequate rinse volumes were used.
- Trichinella larvae were reliably killed during the digestion process to eliminate risk of environmental contamination.
- Kit reagents were not hazardous for analysts.

The artificial digestion magnetic stirrer method using pepsin protease and hydrochloric acid is the standard assay for the detection of Trichinella larvae in muscle of infected animals. Recently, an alternative enzyme, serine protease, was employed in the development of a commercially available digestion kit (PrioCHECK™ Trichinella AAD Kit). This assay requires a higher digestion temperature of 60 °C which kills the larvae during the digestion process, mitigating the risk of environmental contamination from the parasite. The present study was conducted to determine the performance of the PrioCHECK™ Trichinella AAD Kit compared to the conventional pepsin/HCl digestion. Replicate paired 115 g samples of Trichinella-negative pork diaphragm and masseter, and of horse tongue and masseter, were used to compare the two methods for tissue digestibility. Similarly, paired 100 g samples of pork diaphragm and horse tongue were spiked with proficiency samples containing known numbers of Trichinella spiralis first stage larvae to compare larval recoveries for the two methods. Masseter samples from wild bears and wolves naturally infected with Trichinella nativa or T6 were also used to compare the performance of the methods. The results of the study showed that the PrioCHECK™ Trichinella AAD Kit, when used according to the manufacturer's instructions, was effective in detecting Trichinella infection in all samples that contained 0.05 or more larvae per gram of tissue. Although there was no significant difference between the Kit method and the standard pepsin/HCl digestion procedure in the average number of larvae recovered from spiked pork diaphragm, 38% fewer larvae were recovered from similarly spiked samples of horse tongue by digestion using serine protease (one way ANOVA, P value <0.001). Additional clarification was also more often required for both horse meat and pork when using the Kit compared to the pepsin/HCl method. The results of testing wildlife samples were similar for the two methods. Overall, the performance of the Kit method was suitable for the digestion of muscle samples and recovery of Trichinella larvae, according to international standards. It also provides advantages of faster digestion, safer reagents and recovered parasites that are non-hazardous for analysts and the environment.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Veterinary Parasitology - Volume 243, 30 August 2017, Pages 267-271
نویسندگان
, , , , ,