کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5647055 1407076 2017 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Diagnostic accuracy of fractional exhaled nitric oxide measurement in predicting cough-variant asthma and eosinophilic bronchitis in adults with chronic cough: A systematic review and meta-analysis
موضوعات مرتبط
علوم زیستی و بیوفناوری ایمنی شناسی و میکروب شناسی ایمونولوژی
پیش نمایش صفحه اول مقاله
Diagnostic accuracy of fractional exhaled nitric oxide measurement in predicting cough-variant asthma and eosinophilic bronchitis in adults with chronic cough: A systematic review and meta-analysis
چکیده انگلیسی

BackgroundIndividual studies have suggested the utility of fractional exhaled nitric oxide (Feno) measurement in detecting cough-variant asthma (CVA) and eosinophilic bronchitis (EB) in patients with chronic cough.ObjectiveWe sought to obtain summary estimates of diagnostic test accuracy of Feno measurement in predicting CVA, EB, or both in adults with chronic cough.MethodsElectronic databases were searched for studies published until January 2016, without language restriction. Cross-sectional studies that reported the diagnostic accuracy of Feno measurement for detecting CVA or EB were included. Risk of bias was assessed with Quality Assessment of Diagnostic Accuracy Studies 2. Random effects meta-analyses were performed to obtain summary estimates of the diagnostic accuracy of Feno measurement.ResultsA total of 15 studies involving 2187 adults with chronic cough were identified. Feno measurement had a moderate diagnostic accuracy in predicting CVA in patients with chronic cough, showing the summary area under the curve to be 0.87 (95% CI, 0.83-0.89). Specificity was higher and more consistent than sensitivity (0.85 [95% CI, 0.81-0.88] and 0.72 [95% CI, 0.61-0.81], respectively). However, in the nonasthmatic population with chronic cough, the diagnostic accuracy to predict EB was found to be relatively lower (summary area under the curve, 0.81 [95% CI, 0.77-0.84]), and specificity was inconsistent.ConclusionsThe present meta-analyses indicated the diagnostic potential of Feno measurement as a rule-in test for detecting CVA in adult patients with chronic cough. However, Feno measurement may not be useful to predict EB in nonasthmatic subjects with chronic cough. These findings warrant further studies to validate the roles of Feno measurement in clinical practice of patients with chronic cough.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Allergy and Clinical Immunology - Volume 140, Issue 3, September 2017, Pages 701-709
نویسندگان
, , , , , , , , , , , , , , , , , , , , , , ,