کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5668261 1407894 2017 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Chlorhexidine gluconate or polyhexamethylene biguanide disc dressing to reduce the incidence of central-line-associated bloodstream infection: a feasibility randomized controlled trial (the CLABSI trial)
موضوعات مرتبط
علوم زیستی و بیوفناوری ایمنی شناسی و میکروب شناسی میکروبیولوژی و بیوتکنولوژی کاربردی
پیش نمایش صفحه اول مقاله
Chlorhexidine gluconate or polyhexamethylene biguanide disc dressing to reduce the incidence of central-line-associated bloodstream infection: a feasibility randomized controlled trial (the CLABSI trial)
چکیده انگلیسی

SummaryBackgroundA number of antimicrobial-impregnated discs to prevent central-line-associated bloodstream infection (CLABSI) are marketed but it is unclear which disc is most effective.AimTo investigate the feasibility and safety of comparing two antimicrobial-impregnated discs to prevent CLABSI.MethodsA single-centre, parallel group, randomized controlled trial was conducted in a 929-bed tertiary referral hospital. Hospital inpatients requiring a peripherally inserted central catheter were randomized to chlorhexidine gluconate (CHG) or polyhexamethylene biguanide (PHMB) disc dressing group. Dressings were replaced every seven days, or earlier, if clinically required. Participants were followed until device removal or hospital discharge. Feasibility outcomes included: proportion of potentially eligible participants who were enrolled; proportion of protocol violations; and proportion of patients lost to follow-up. Clinical outcomes were: CLABSI incidence, diagnosed by a blinded infection control practitioner; all-cause bloodstream infection (BSI); and product-related adverse events.FindingsOf 143 patients screened, 101 (71%) were eligible. Five (3.5%) declined participation. There was one post-randomization exclusion. Two (2%) protocol violations occurred in the CHG group. No patients were lost to follow-up. Three (3%) BSIs occurred; two (2%) were confirmed CLABSIs (one in each group) and one a mucosal barrier injury-related BSI. A total of 1217 device-days were studied, resulting in 1.64 CLABSIs per 1000 catheter-days. One (1%) disc-related adverse event occurred in the CHG group.ConclusionDisc dressings containing PHMB are safe to use for infection prevention at catheter insertion sites. An adequately powered trial to compare PHMB and CHG discs is feasible.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Hospital Infection - Volume 96, Issue 3, July 2017, Pages 223-228
نویسندگان
, , , , , ,