کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5731736 1611936 2017 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Original ResearchApplication of a narrow-surface cage in full endoscopic minimally invasive transforaminal lumbar interbody fusion
ترجمه فارسی عنوان
تحقیق اصلی استفاده از یک قفس باریک در انتواسکوپی کمترین تهاجمی ترانسفارمینال کمپلکس بینابینی کمری
کلمات کلیدی
جراحی حداقل مهاجم ستون فقرات، اندوسکوپی، همجوشی بینابینی کمری، قفس فیوژن
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی عمل جراحی
چکیده انگلیسی


- Endoscopic lumbar interbody fusion still remains a technical challenge.
- An 8-mm-wide narrow-surface cage was selected for 42 cases underwent endoscopic lumbar interbody fusion.
- All procedures were performed safely and successfully with minimal trauma and improved visualization.
- Clinical outcome and fusion rate of narrow-surface cage were acceptable and promising.

BackgroundSpinal endoscopy has been widely applied in lumbar discectomy and decompression. However, endoscopic lumbar interbody fusion still remains a technical challenge due to the limited space within the working trocar for cage implantation. The purpose of this study was to investigate the feasibility and effectiveness of using a narrow-surface fusion cage in full endoscopic minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) for the treatment of lumbar degenerative disease.Materials and MethodsFrom Jun 2013 to Dec 2014, a total of 42 patients (23 males, 19 females) underwent full endoscopic MIS-TLIF at our hospital was recruited. An 8-mm-wide narrow-surface fusion cage was selected for all cases. Perioperative parameters and complications were recorded. Comparisons on visual analog scale (VAS) and oswestry disability index (ODI) scores before and after surgery were performed. At the last follow-up, Nakai grading system was applied to assess patients' satisfaction; meanwhile, interbody fusion was evaluated by computed tomography.ResultsMean operation time was 233.1 ± 69.5 min, and mean blood loss during surgery was 221.8 ± 98.5 ml. Two patients (4.8%) developed neurological complications. Postoperative follow-up ranged from 24 to 36 months (mean 27.6 ± 3.8 months). VAS and ODI scores were significantly improved 3 months after surgery and at the final follow-up, respectively (P < 0.05). Outcome of surgery was graded as excellent for 32 patients, good for 8 patients, and acceptable for 2 patients, corresponding to a success rate (“good” and “excellent”) of 95.2%. Thirty-nine of the 42 patients demonstrated solid interbody fusion at the last follow-up, indicating a fusion rate of 92.9%.ConclusionApplication of a narrow-surface fusion cage in full endoscopic MIS-TLIF for the treatment of lumbar degenerative disease is feasible and effective. The clinical outcome and fusion success of this procedure were acceptable and promising.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: International Journal of Surgery - Volume 42, June 2017, Pages 83-89
نویسندگان
, , , , , ,