کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5943117 1574715 2016 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
In vivo detection of atherosclerotic plaque using non-contact and label-free near-infrared hyperspectral imaging
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
In vivo detection of atherosclerotic plaque using non-contact and label-free near-infrared hyperspectral imaging
چکیده انگلیسی


- We establish a non-contact and label-free NIR HSI system for identifying plaques.
- NIR spectra show different patterns between arteries with and without plaque.
- Combining with the HSI and SVM, precise locations of plaques can be predicted.
- Our method can less invasively evaluate detailed atherosclerotic lesions in vivo.

Background and aimsDetecting detailed atherosclerotic plaques is important to reduce risk factors during surgery. However, there are few methods to evaluate them during surgery. The aim of this study was to establish an in vivo, non-contact, and label-free imaging method for identifying atherosclerotic plaque lesions from outside vessels with a diffuse-reflectance near-infrared (NIR) hyperspectral imaging (HSI) system.MethodsNIR spectra between 1000 and 2350 nm were measured using an NIR HSI imaging system outside the exposed abdominal aorta in five Watanabe Heritable Hyperlipidemic (WHHL) rabbits in vivo. Preprocessed data were input to a supervised machine learning algorithm called a support vector machine (SVM) to create pixel-based images that can predict atherosclerotic plaques within a vessel. The images were compared with histological findings.ResultsAbsorbance was significantly higher in plaques than in normal arteries at 1000-1380, 1580-1810, and 1880-2320 nm. Overall predictive performance showed a sensitivity of 0.814 ± 0.017, a specificity of 0.836 ± 0.020, and an accuracy of 0.827 ± 0.008. The area under the receiver operating characteristic curve was 0.905 (95% confidence interval = 0.904-0.906).ConclusionsThe NIR HSI system combined with a machine learning algorithm enabled accurate detection of atherosclerotic plaques within an internal vessel with high spatial resolution from outside the vessel. The findings indicate that the NIR HSI system can provide non-contact, label-free, and precise localization of atherosclerotic plaques during vascular surgery.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Atherosclerosis - Volume 250, July 2016, Pages 106-113
نویسندگان
, , , , , , ,