کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5980663 1177010 2015 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Prospective Assessment of the Diagnostic Accuracy of Instantaneous Wave-Free Ratio to Assess Coronary Stenosis Relevance: Results of ADVISE II International, Multicenter Study (ADenosine Vasodilator Independent Stenosis Evaluation II)
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Prospective Assessment of the Diagnostic Accuracy of Instantaneous Wave-Free Ratio to Assess Coronary Stenosis Relevance: Results of ADVISE II International, Multicenter Study (ADenosine Vasodilator Independent Stenosis Evaluation II)
چکیده انگلیسی

ObjectivesThe purpose of this study was to assess the diagnostic accuracy of the instantaneous wave-free ratio (iFR) to characterize, outside of a pre-specified range of values, stenosis severity, as defined by fractional flow reserve (FFR) ≤0.80, in a prospective, independent, controlled, core laboratory-based environment.BackgroundStudies with methodological heterogeneity have reported some discrepancies in the classification agreement between iFR and FFR. The ADVISE II (ADenosine Vasodilator Independent Stenosis Evaluation II) study was designed to overcome limitations of previous iFR versus FFR comparisons.MethodsA total of 919 intermediate coronary stenoses were investigated during baseline and hyperemia. From these, 690 pressure recordings (n = 598 patients) met core laboratory physiology criteria and are included in this report.ResultsThe pre-specified iFR cut-off of 0.89 was optimal for the study and correctly classified 82.5% of the stenoses, with a sensitivity of 73.0% and specificity of 87.8% (C statistic: 0.90 [95% confidence interval (CI): 0.88 to 0.92, p < 0.001]). The proportion of stenoses properly classified by iFR outside of the pre-specified treatment (≤0.85) and deferral (≥0.94) values was 91.6% (95% CI: 88.8% to 93.9%). When combined with FFR use within these cut-offs, the percent of stenoses properly classified by such a pre-specified hybrid iFR-FFR approach was 94.2% (95% CI: 92.2% to 95.8%). The hybrid iFR-FFR approach obviated vasodilators from 65.1% (95% CI: 61.1% to 68.9%) of patients and 69.1% (95% CI: 65.5% to 72.6%) of stenoses.ConclusionsThe ADVISE II study supports, on the basis rigorous methodology, the diagnostic value of iFR in establishing the functional significance of coronary stenoses, and highlights its complementariness with FFR when used in a hybrid iFR-FFR approach. (ADenosine Vasodilator Independent Stenosis Evaluation II-ADVISE II; NCT01740895)

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: JACC: Cardiovascular Interventions - Volume 8, Issue 6, May 2015, Pages 824-833
نویسندگان
, , , , , , , , , , , , , , , , , , , , , , ,