عنوان انگلیسی مقاله ISI
The effect of total hip and hip resurfacing arthroplasty on vertical ground reaction force and impulse symmetry during a sit-to-stand task
ترجمه فارسی عنوان
تأثیر آرتروپلاستی مجدد لگن و لگن بر روی نیروی واکنش زمین عمودی و تقارن امپدانس در طول یک کار مستقل
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
چکیده انگلیسی


- Total or resurfacing hip arthroplasty patients performed a sit-to-stand task.
- Ground reaction force under both feet was used to determine limb loading symmetry.
- Both groups overloaded the non-operated leg 3 months after surgery.
- Total hip patients returned to a symmetrical loading pattern after 12 months.
- Hip resurfacing patients overloaded their operated limb after 12 months.

BackgroundThe aim of this study was to determine the influence of total hip arthroplasty and hip resurfacing arthroplasty on limb loading symmetry before, and after, hip reconstruction surgery during a sit-to-stand task.MethodsFourteen patients were recruited that were about to receive either a total hip prosthesis (n = 7) or a hip resurfacing prosthesis (n = 7), as well as matched controls. Patients performed a sit-to-stand movement before, 3 months after, and 12 months after surgery. Peak vertical ground reaction force and impulse were measured for each leg, from which ground reaction force and impulse symmetry ratios were calculated.FindingsBefore surgery, hip resurfacing patients showed a small asymmetry which was not different to normal for ground reaction force (0.88(0.28) vs. 1.00(0.11); p = 0.311) or impulse (0.87(0.29) vs. 0.99(0.09); p = 0.324) symmetry ratios. Total hip patients offloaded their affected hip by 30% in terms of impulse symmetry ratio (0.71(0.36) vs. 0.99(0.23); p = 0.018). At 3 months following surgery asymmetries were seen that were different to normal in both hip resurfacing patients for ground reaction force (0.77(0.16); p = 0.007), and total hip patients for ground reaction force (0.70(0.15); p = 0.018) and impulse (0.72(0.16); p = 0.011) symmetry ratios. By 12 months after surgery total hip patients regained a symmetrical loading pattern for both ground reaction force (0.95(0.06); p = 0.676) and impulse (1.00(0.06); p = 0.702) symmetry ratios. Hip resurfacing patients, however, performed the task by overloading their operated hip, with impulse symmetry ratio being larger than normal (1.16(0.16); p = 0.035).InterpretationPhysiotherapists should appreciate the need for early recovery of limb loading symmetry as well as subsequent differences in the responses observed with different prostheses.