کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
651769 1457438 2012 14 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Kinematic characterization of the advancing liquid–gas interface in microfluidic components combining digital processing of microscope images with curve matching technique
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی جریان سیال و فرایندهای انتقال
پیش نمایش صفحه اول مقاله
Kinematic characterization of the advancing liquid–gas interface in microfluidic components combining digital processing of microscope images with curve matching technique
چکیده انگلیسی

A method based on flow visualization to measure the advancing planar liquid–gas interface velocities of unsteady two-phase microflows is presented. A high-frequency CCD camera connected to a microscope is used to acquire flow images, which are digitally processed to define mathematically the interface locations at each frame of the acquired images with accuracy of ±½ pixel. Curve matching technique including a function to define the optimal matching path is applied to the parameterized interface locations previously obtained to determine the advancing interface velocities. The continuity equation is included in the algorithm to evaluate the velocity profile that minimizes the mass imbalance. The method is appropriate for open curves typical of moving interfaces inside confined microdevices and is applied to the filling process flows at constant rate, imposed by a syringe pump, in two constant height microchannels with different sizes for validation purposes. The results yielded by the methodology prove that it is accurate in determining planar flows with no vertical velocity component with mass balance errors below 0.07%. When a relevant vertical velocity component is present, the technique is hardly applicable to such flows since it is unable to capture the interface movement in that direction, yielding errors of mass balance that can go up to 41.6% in the case of a triangular microvalve with varying height.


► Microflow visualization is used to measure velocities of moving liquid interfaces.
► Digital image processing defines interface location functions with ½ pixel accuracy.
► Curve matching computes interface velocities using those functions and continuity equation.
► The method is applied to filling processes in microchannels.
► Results for planar moving interfaces exhibit mass balance errors below 0.07%.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Experimental Thermal and Fluid Science - Volume 38, April 2012, Pages 40–53
نویسندگان
, ,