کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
652400 885019 2007 13 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Heat transfer and pressure drop in tube with broken twisted tape insert
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی جریان سیال و فرایندهای انتقال
پیش نمایش صفحه اول مقاله
Heat transfer and pressure drop in tube with broken twisted tape insert
چکیده انگلیسی

An experimental study measuring the axial heat transfer distributions and the pressure drop coefficients of the tube fitted with a broken twisted tape of twist ratio 1, 1.5, 2, 2.5 or ∞ is performed in the Re range of 1000–40,000. This type of broken twisted tape is newly invented without previous investigations available. Local Nusselt numbers and mean Fanning friction factors in the tube fitted with the broken twisted tape increase as the twist ratio decreases. Heat transfer coefficients, mean Fanning friction factors and thermal performance factors in the tube fitted with the broken twisted tape are, respectively, augmented to 1.28–2.4, 2–4.7 and 0.99–1.8 times of those in the tube fitted with the smooth twisted tape. Empirical heat transfer and pressure drop correlations which evaluate the local Nusselt number and the mean Fanning friction factor for the tube with the broken twisted tape insert are generated to assist the industrial applications.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Experimental Thermal and Fluid Science - Volume 32, Issue 2, November 2007, Pages 489–501
نویسندگان
, , ,