کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4473820 1315108 2008 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Investigation on the heavy-metal content of zinc-air button cells
موضوعات مرتبط
مهندسی و علوم پایه علوم زمین و سیارات مهندسی ژئوتکنیک و زمین شناسی مهندسی
پیش نمایش صفحه اول مقاله
Investigation on the heavy-metal content of zinc-air button cells
چکیده انگلیسی

Within the framework of a German government project (initiated by the Federal Environment Agency) to check the compliance of commercially available batteries with the German Battery Ordinance concerning their heavy metal contents, 18 different types of commercially available zinc-air button cells were analysed for their cadmium, lead and mercury contents. After microwave assisted dissolution with aqua regia, Cd and Pb were determined using inductively coupled plasma mass spectrometry (ICP-MS), and Hg was determined using inductively coupled plasma optical emission spectrometry (ICP OES) and atomic absorption spectrometry. Cd contents were found to be much lower than the permitted limits; Pb contents were also found to be below the limits. Hg contents were found to be near the limits, and in one case the limit was exceeded.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Waste Management - Volume 28, Issue 8, 2008, Pages 1493–1497
نویسندگان
, , ,