Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
10078947 | Arthroscopy: The Journal of Arthroscopic & Related Surgery | 2005 | 5 Pages |
Abstract
Purpose: Bioabsorbable interference screw design may influence biomechanical characteristics. This study compared the insertion torque and load at failure characteristics of 2 types of screws during retrograde fixation of a soft-tissue graft. Type of Study: Biomechanical study. Methods: Eight matched pairs of doubled 100-mm long tibialis anterior allografts were prepared and fixed in appropriately sized tunnels created in 10 lb/ft3 (0.16 g/cm3) dense synthetic bone blocks using screws of similar length and root and thread diameter designed with either a large buttress thread with a smaller taper or small buttress thread with a larger taper. Insertion torque was measured at one-third, two-thirds, and full screw insertion. After the graft fixation constructs were mounted in a servohydraulic-testing device with the loading axis aligned directly with the tunnel and preloaded to 25 N, they were cycled 3 times from 0 to 50 N, and then subjected to a 20 mm/minute traction force to failure. Results: All constructs failed by graft slippage past the screw. Mean maximum load at failure (360.5 ± 68 N v 341.6 ± 58 N, P = .2) and stiffness (63.6 ± 16 N/mm2v 66.4 ± 14 N/mm2, P = .89) was similar between constructs fixed with a large buttress thread small-taper screw and small buttress thread large-taper screw, respectively. The small buttress thread screw with a large taper displayed greater mean insertion torque at one-third insertion (4.1 ± 0.57 in-lb v 3.2 ± 0.49 in-lb, P = .03), whereas the large buttress thread screw with a small taper displayed greater mean insertion torque at full insertion (11.1 ± 0.74 in-lb v 9.4 ± 1.3 in-lb, P = .012). Mean differences were not observed at two-thirds screw insertion (P = .12). Conclusions: Large buttress thread small-taper screws displayed biomechanical fixation characteristics comparable to small buttress thread large-taper screws. Clinical Relevance: Given reports of superior screw-graft-bone tunnel contact area, these biomechanical results suggest that use of a large buttress screw with a small taper may be preferable for retrograde soft-tissue graft fixation.
Related Topics
Health Sciences
Medicine and Dentistry
Orthopedics, Sports Medicine and Rehabilitation
Authors
Tanya D. M.S., Yavuz M.D., Scott M.D., John Ed.D., P.T. S.C.S., A.T.C., David N.M. M.D.,