Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
10081692 | The Journal of Arthroplasty | 2005 | 6 Pages |
Abstract
Fifteen knee arthrodeses using an intramedullary nail were performed in 15 patients. Indications included 11 failed total knee arthroplasties (10 of 11 septic). A retrospective review revealed 100% fusion rate. Complications included 4 cases of painful hardware, 1 trochanteric bursitis, and 1 deep infection. Ten patients were available for assessment at 7 years follow-up. Average leg length discrepancy was 3.7 cm. Anatomic axis averaged 1.3° valgus. Flexion angle averaged 3.5°. Compared with age-matched controls, our patients fared significantly worse in physical functioning, physical role, bodily pain, vitality, and social functioning. Arthrodesis of the knee with an intramedullary nail provides a reliable means of fusion with reasonable alignment. These patients have high rates of pain and diminished functional status.
Keywords
Related Topics
Health Sciences
Medicine and Dentistry
Orthopedics, Sports Medicine and Rehabilitation
Authors
John R. MD, Marc J. MD,