Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
10081731 | The Journal of Arthroplasty | 2005 | 7 Pages |
Abstract
Sixty-seven hips in 63 patients who underwent total hip arthroplasties with the use of the nonmodular cementless acetabular component and alumina-on-polyethylene bearing surface were available for complete clinical and radiographic review at a mean follow-up period of 7 (range 5-9) years. The mean age was 59 years (range 34-75) years. The mean preoperative Harris hip score of 50 points improved to 93 points at final follow-up. One (1.5%) hip required revision for a recurrent dislocation. No component was loose radiographically at final follow-up. The mean linear wear rate was 0.07 (range 0.01-0.23) mm/y. At a mean follow-up of 7 years, there was no aseptic loosening. Further follow-up, however, is necessary to determine the potential advantage of nonmodular acetabular component for the development of pelvic osteolysis.
Keywords
Related Topics
Health Sciences
Medicine and Dentistry
Orthopedics, Sports Medicine and Rehabilitation
Authors
Shin-Yoon MD, Do-Heon MD, Chang-Wug MD, Poong-Taek MD, Joo-Chul MD, Suk-Young PhD,