Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
10123408 | British Journal of Anaesthesia | 2005 | 5 Pages |
Abstract
Using 50% helium-oxygen during HFJV in the presence of airway stenosis allows an 18% increase in minute volume at generated airway pressures which are the same as or lower than those when using 100% oxygen.
Related Topics
Health Sciences
Medicine and Dentistry
Anesthesiology and Pain Medicine
Authors
P.W. Buczkowski, F.N. Fombon, W.C. Russell, J.P. Thompson,