Abstract
The analyses showed that the components underwent to a severe Stress Corrosion Cracking (SCC) stimulated by the presence, in the working environment, of atmospheric condenses together with high chlorides containing EAF dusts.
Related Topics
Physical Sciences and Engineering
Engineering
Industrial and Manufacturing Engineering
Authors
A. Lanzutti, M. Magnan, S. Maschio, L. Fedrizzi,