Article ID Journal Published Year Pages File Type
10221360 The Journal of Arthroplasty 2018 5 Pages PDF
Abstract
To the authors' knowledge, this is the first study to identify femoral anteversion as an independent factor influencing XLPE wear, with least wear occurring around 18°. At 5-10 years, average linear wear of XLPE is below 0.1 mm/y over a 25°-50° range of combined anteversion, with the least wear around 38°. Femoral-acetabular mating is a product of both components. Femoral component version and combined anteversion had a greater effect on wear than acetabular component lateral opening angle. Additional studies are warranted, but these results indicate that the sensitivity of wear studies is increased with version assessments.