Article ID Journal Published Year Pages File Type
10281013 Powder Technology 2005 9 Pages PDF
Abstract
Experimental data reveal that the electric field of a filter treated with anionic surfactant (SO) could be directly measured using an electrofieldmeter, suggesting that the pretreatment with surfactant charged the filters. The results demonstrate that pretreating the filter with SO surfactant increases its particle-loading capacity. The clogging points of the untreated filter, and of the 0.01, 0.05 and 0.08 M SO-pretreated filter are 18, 23, 28 and 33 g/m2. The loading behavior of the SO-pretreated filter depended on the size of the particles and the operating face velocity. Additionally, the loading behavior of the SO-pretreated filter with polydisperse particles is much the same as that with monodisperse particles. However, the clogging point of the SO-pretreated filter with polydisperse particles is higher than that with monodisperse equal size.
Related Topics
Physical Sciences and Engineering Chemical Engineering Chemical Engineering (General)