Article ID Journal Published Year Pages File Type
10288796 Journal of Constructional Steel Research 2005 22 Pages PDF
Abstract
Test results on concrete-filled steel tubular stub columns with inner or outer welded longitudinal stiffeners under axial compression are presented in this paper. The research was mainly focused on square hollow section (SHS) columns; two rectangular hollow section (RHS) columns were also tested. A longitudinal stiffener was provided on each side of the stiffened SHS column, while only two stiffeners were welded to the longer sides of the stiffened RHS column. The main experimental parameters considered were the height-to-thickness ratio and stiffener rigidity. In addition, empty tubes with or without stiffeners, as well as unstiffened concrete-filled steel tubes were also tested for comparison. Requirements for stiffener rigidity are developed by modifying a formula presented in the literature. Existing theoretical model and design codes were used to predict the load versus axial strain relationships and load-carrying capacities of the adequately stiffened composite sections respectively; reasonable results were achieved.
Related Topics
Physical Sciences and Engineering Engineering Civil and Structural Engineering
Authors
, , ,