Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
10293398 | Nuclear Engineering and Design | 2005 | 20 Pages |
Abstract
A one-dimensional model is presented to predict counter-current flow limitations during hot leg injection in pressurized water reactors. Different from previous models, it may also be applied in case of high Froude numbers of the liquid flow, such as to be expected in the case of emergency coolant injection through the hot leg. The model has been verified with an extensive experimental program performed in the WENKA test facility at the Forschungszentrum Karlsruhe. Typical flow regimes were investigated for a wide range of flow conditions, simulated with air and water at ambient pressure and temperature, in a simplified Pressurized Water Reactor (PWR) hot leg geometry. Depending on the water and air flow rates, flow phenomena such as a hydraulic jump and flow reversal were experimentally observed. The theoretical model shows that not only the nondimensional superficial velocities of liquid and gas, but also the Froude number of the liquid at the injection point and the Reynolds number of the gas play an important role for the prediction of flow reversal. In case of a high liquid inlet Froude number, a flow reversal could only be observed if the liquid flow became locally subcritical, i.e. if a hydraulic jump occurred in the channel. The flow reversal is predicted by the presented model with good accuracy.
Related Topics
Physical Sciences and Engineering
Energy
Energy Engineering and Power Technology
Authors
M. Gargallo, T. Schulenberg, L. Meyer, E. Laurien,