Article ID Journal Published Year Pages File Type
10296499 Tunnelling and Underground Space Technology 2005 10 Pages PDF
Abstract
Detailed analyses of smoke movement from a burning vehicle in a road tunnel have been carried out for the westbound Melbourne City Link tunnel. The time-averaged equations for velocity, pressure, temperature, and mass fraction of emissions were solved for transient condition using the CFD software FLUENT 6.0. For the analysis, a burning bus was assumed to release an equivalent energy of burning 500 l of diesel in 6 min, with vehicles upstream of the fire at a standstill. On the other hand, the vehicles downstream of the fire had enough time to escape from the tunnel through the exit portal. Due to the action of jet fans, most of the smoke was pushed downstream of the fire. The smoke had also dispersed about 55 m upstream of the fire, putting the passengers in this region at great risk. The emissions released from the vehicles in the jam, with their engines running, also posed a threat to human health. Within 8 min after the fire had started, the mass concentrations of O2, CO2 and CO were in the ranges of 0.12-0.15, 0.08-0.11 and 0.0006-0.0014, respectively. Therefore, quick evacuation of the passengers is essential in the event of a fire in the tunnel.
Related Topics
Physical Sciences and Engineering Earth and Planetary Sciences Geotechnical Engineering and Engineering Geology
Authors
, ,