Abstract
Magnetic Flux Leakage detector (MFL_PIG) is widely used in long-range pipeline inspection. Acoustic above ground marking device is an important part of the location system in the MFL_PIG. A novel above ground marking algorithm based on function fitting is proposed to reduce marking error of above ground markers (AGMs). Experiments were carried out on a 2.5Â km long pipeline on site. The results demonstrate that the function fitting algorithm has higher precision and anti-interference ability than traditional marking method-extreme value algorithm, and it works very well when SNR of the signal is greater than â2Â dB.
Keywords
Related Topics
Physical Sciences and Engineering
Engineering
Control and Systems Engineering
Authors
Yibo Li, Dian Wang, Liying Sun,