Article ID Journal Published Year Pages File Type
10410752 Optics and Lasers in Engineering 2005 11 Pages PDF
Abstract
A method of two-step digital image correlation is well developed with more stable and reliable calculating technology, which consists of a simple searching method and an iterative correlation method. This new method can not only improve the calculating speed and the measuring accuracy, but also simplify the process of the experiment. In order to further increase the sensitivity of the technique, the sub-pixel reconstruction is performed in sub-image by utilizing the higher precision calculation of bicubic spline interpolation value method, and the accuracy of displacement is extended to better than 0.01 pixel; the strain resolution is limited to less than 0.0002 in micro-region. The above method is applied to quantify the micro-deformation of bimaterial sample and coating sample. The experimental results show that the method of two-step digital image correlation is a potential boon to investigations at extremely small-size scales.
Related Topics
Physical Sciences and Engineering Engineering Electrical and Electronic Engineering
Authors
, , , , ,