Article ID Journal Published Year Pages File Type
10415247 Engineering Fracture Mechanics 2005 22 Pages PDF
Abstract
The virtual crack closure integral (VCCI) method is used to evaluate the stress intensity factor (SIF) and energy release rate (ERR) of an interface crack under thermal load. The VCCIs used in this work include the traditionally known “Mode I” and “Mode II” VCCIs and an additional coupling VCCI. The singularity element is used in the finite element method (FEM) implementation. The SIF and ERR calculated by the FEM are compared to the exact solution in the case of a joint dissimilar semi-infinite plates with double edge crack under thermal loading. The FEM result agrees well with the exact solution for relatively coarse meshes. The contribution of the mesh density and material mismatch to the FEM error is also explored. The VCCI method is used with the multi-scale FEM in a delamination risk assessment of a low-k integrated circuits device in flip-chip plastic ball grid array packages. The ERR is calculated for different package configurations and the prediction of the delamination risk is confirmed by reliability tests.
Related Topics
Physical Sciences and Engineering Engineering Mechanical Engineering
Authors
,