Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
10417694 | Journal of Materials Processing Technology | 2013 | 10 Pages |
Abstract
⺠Current, voltage and temperature measurements were performed to clarify the operation of the SPS. ⺠High frequency voltage and current measures shows there is no inductive effect in the SPS column. ⺠These measures enable us to improve an electro-thermal model by the finite element method (FEM). ⺠Use of RMS voltage, chamber temperature, graphite properties lead to more realistic simulations.
Keywords
Related Topics
Physical Sciences and Engineering
Engineering
Industrial and Manufacturing Engineering
Authors
A. Pavia, L. Durand, F. Ajustron, V. Bley, G. Chevallier, A. Peigney, C. Estournès,