The use of PRA in the early stages of the design has allowed a selection of design and performance features and an optimization of the design of several systems to reduce the potential for events that could lead to core damage via both enhanced prevention and mitigation of challenges. As a result, the total core damage frequency for internal events for the IRIS design has been calculated as 1.2×10−8 per year.