Abstract
All acceleration measurement and processing techniques were based on well-established practices and standards. These proved to be reliable and reproducible. Potential errors in the linear accelerations due to electrical or mechanical noise did not exceed 2% for the three different noise sources investigated. Potential errors in the angular accelerations due to noise could be as high as 6.7%, due to error accumulation of multiple linear acceleration measurements. The potential error in the relative impact velocity between colliding heads could be as high as 11%, and was found to be the largest error source in the sequence of techniques to reconstruct the game impacts. Full-scale experiments with complete crash test dummies in staged head impacts showed maximum errors of 17% for resultant linear accelerations and 25% for resultant angular accelerations.