Article ID Journal Published Year Pages File Type
10554146 Journal of Pharmaceutical and Biomedical Analysis 2005 7 Pages PDF
Abstract
An improved column switching high performance liquid chromatographic (HPLC) method was developed for determination of cetirizine in human plasma. Plasma samples were prepared by liquid-liquid extraction using methylene chloride. The samples extracted were initially injected into a clean-up Capcell Pak MF C8 column and the peaks of cetirizine and internal standard were separated to an analytical C18 micro-column via column switching device. This analysis showed highly sensitive and selective results. Also, it was successfully applied to evaluate the pharmacokinetics of cetirizine in human volunteers after single oral administration.
Related Topics
Physical Sciences and Engineering Chemistry Analytical Chemistry
Authors
, , , , , , , ,