Abstract
Humic substances (HS) and other substance of similar nature (“building blocks” of HS, such as salicylates or phthalates) influence strongly a polarographic behaviour of europium at a mercury drop electrode. An addition of these substances into the supporting electrolyte causes an enhancement of the differential pulse polarographic (DPP) peak of Eu and an anodic shift of the maximum peak potential. It was deduced from the dependence of the peak height on the pulse time and from other experimental dependencies that an adsorption of the Eu-HS (salicylate, phthalate) complexes on the working electrode is the main mechanism responsible for the peak enhancement. Because no peak distortion or splitting were observed, the DPP determination of Eu can be realised readily in the presence of HS, e.g. in environmental samples. The sensitivity of the measurements increased in the presence of HS, whereas the limit of detection (LOD) decreased (LODs were 255 and 140 nmol/l in the absence and in the presence of HS, respectively). However, the calibration dependencies were non-linear in the presence of HS. It was found that the non-linear calibration dependencies may be approximated by the Langmuir-type equation. Special procedures, such as a method of (at least) two standard additions and numerical iterative calculations, are necessary for an evaluation of measurements.
Related Topics
Physical Sciences and Engineering Chemistry Analytical Chemistry