Abstract
The aim of this study was to demonstrate the feasibility of using a steam autoclave process for sterilization and simultaneously thermal-crosslinking of lyophilized chitosan scaffolds. This process is of great interest in biomaterial development due to its simplicity and low toxicity. The steam autoclave process had no significant effect on the average pore diameter (~ 70 μm) and overall porosity (> 80%) of the resultant chitosan scaffolds, while the sterilized scaffolds possessed more homogenous pore size distribution. The sterilized chitosan scaffolds exhibited an enhanced compressive modulus (109.8 kPa) and comparable equilibrium swelling ratio (23.3). The resultant chitosan scaffolds could be used directly for in vitro cell culture without extra sterilization. The data of in vitro studies demonstrated that the scaffolds facilitated cell attachment and proliferation, indicating great potential for soft tissue engineering applications.