Article ID Journal Published Year Pages File Type
10622841 Cement and Concrete Research 2005 12 Pages PDF
Abstract
The introduction of superplasticizers (Sp) in the production of concrete has produced highly flowable mixtures with enhanced viscosity. In cases of optimum flowability and viscosity, for example self-compacting concrete (SCC), no vibration is necessary for placement. However, such ideal conditions are not practically easy to achieve and deviations are possible. This paper reviews the results of a study to investigate the vibration of such high fluidity concrete. Two criteria were used to characterize the fresh mix, that is, slump flow and V-funnel time (V-time). Firstly, the feasibility of vibration on such mixes was studied. Then, the significance of flowability and viscosity was determined. Next, the relationship between workability and its segregation tendency was investigated. Finally, concrete mixes that missed SCC criteria were vibrated. Three different scenarios of vibration were concluded: namely, mix that accept vibration freely, mix that required controlled vibration and mix that needed prior treatment of viscosity enhancing agent (VEA) before vibration.
Related Topics
Physical Sciences and Engineering Engineering Industrial and Manufacturing Engineering
Authors
, , ,