Article ID Journal Published Year Pages File Type
10682690 Energy 2012 8 Pages PDF
Abstract
▸ A combustion system of a down-fired 350 MWe supercritical utility boiler was designed. ▸ Aerodynamic characteristics were obtained, and analyzed the velocity distribution within a cold 1:10 scaled model. ▸ Impart of various primary air to vent air ratios were investigated on aerodynamic field to find effect on downward flow.
Related Topics
Physical Sciences and Engineering Energy Energy (General)
Authors
, , , , , , ,