Article ID Journal Published Year Pages File Type
10686907 Journal of Environmental Radioactivity 2005 9 Pages PDF
Abstract
This paper reports on radon concentrations in dwellings from fifty different locations of India. The incorporated data were obtained using the passive solid state nuclear track detector technique. The estimated geometric mean value for India is 67.1 Bq m−3. Chuadanga in Bangladesh had the lowest observed indoor radon concentration of 27.3 Bq m−3 and Una in the northern part of India had the highest concentration of 281.5 Bq m−3. This paper discusses the national geometrical mean value in terms of the national geometric mean values of other countries and also in terms of the geological influence. The estimated indoor radon levels are compared with the indoor radon levels as recommended by the International Commission on Radiation Protection (ICRP). It was observed that there are several locations in India where dwellings have higher indoor radon levels than the ICRP recommended value and requires some sort of intervention from regulating authorities. The mean value for indoor radon level given in the report of UNSCEAR 2000 for India needs to be revised.
Related Topics
Physical Sciences and Engineering Energy Nuclear Energy and Engineering