Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
10688294 | Journal of Cleaner Production | 2005 | 10 Pages |
Abstract
The dynamic characteristics of reactive absorption processes are of great importance for the smooth operation of the unit and the overall performance of the implemented control system under the influence of process disturbances and the presence of tight environmental and safety constraints. In the present study, the effect of the major design parameters and column configurations on the dynamic behaviour of the environmentally sensitive NOx removal processes, through the use of rigorous rate-based dynamic models, is investigated. Static and dynamic disturbance rejection properties are evaluated for the screening and assessment of alternative design decisions.
Related Topics
Physical Sciences and Engineering
Energy
Renewable Energy, Sustainability and the Environment
Authors
Natassa Dalaouti, Panos Seferlis,