A non-linear control method, known as Variable Structure Control (VSC), is employed to reduce the duration of ultrasonic (US) transducer transients. A physically realizable system using a simplified form of the VSC algorithm is proposed for standard piezoelectric transducers and simulated. Results indicate a VSC-controlled transmitter reduces the transient duration to less than a carrier wave cycle. Applications include high capacity ultrasound communication and localization systems.
Related Topics
Physical Sciences and Engineering Physics and Astronomy Acoustics and Ultrasonics