Article ID Journal Published Year Pages File Type
10690597 Ultrasonics 2013 7 Pages PDF
Abstract
► Three flaws in the same wire can be detected using the low frequency guided wave. ► Only the first flaw is detected using the high frequency guided wave. ► The elastic energy exchange between wires decreases as the frequency increases. ► We observe the recovery length for elastic waves in the prestressing strand. ► A method for distinguishing flaws in different wires or the same wire is provided.
Related Topics
Physical Sciences and Engineering Physics and Astronomy Acoustics and Ultrasonics