Abstract
US speed, attenuation and IBC were estimated from standard methods described in the literature. Statistical tests were applied to the results of each parameter individually and indicated that it was not possible to identify all the fibrosis groups. Then a discriminant analysis was performed for the three parameters together resulting in a reasonable separation of fibrotic groups. Although the number of tissue samples is limited, this study opens the possibility of enhancing the discriminant capability of ultrasonic parameters of liver tissue disease when they are combined together.
Related Topics
Physical Sciences and Engineering Physics and Astronomy Acoustics and Ultrasonics