Article ID Journal Published Year Pages File Type
10691336 Ultrasound in Medicine & Biology 2015 12 Pages PDF
Abstract
A 30-MHz ultrasonic scanner was used to collect B-scan images together with appropriate radiofrequency echoes from diseased and healthy skin regions of patients with diagnosed basal cell carcinoma and pre-cancerous lesions (actinic keratosis). Radiofrequency data were processed to obtain the attenuation coefficient and statistics of the backscattered echo signal determination (K-distribution and effective density of scatterers [EDS]). The attenuation coefficient was significantly higher for patients with basal cell carcinoma than for healthy patients. Also, the pre-cancerous skin lesions had increased attenuation. The averaged EDS values for cancer lesions were significantly lower than those for pre-cancerous lesions and healthy skin. The successful differentiation between the tissue groups examined suggests the potential value of the attenuation coefficient and EDS for carcinoma characterization.
Related Topics
Physical Sciences and Engineering Physics and Astronomy Acoustics and Ultrasonics
Authors
, , , ,