Abstract
Dose values measured during four solar proton events by the onboard dosimeters in different points of the Russian module are given. Estimations of equivalent dose in critical organs and adequate effective dose for spherical phantom are presented.
Related Topics
Physical Sciences and Engineering
Earth and Planetary Sciences
Space and Planetary Science
Authors
V.V. Benghin, V.M. Petrov, S.A. Kireeva, A.V. Markov, A.N. Volkov, A.P. Aleksandrin, M.I. Panasjuk, J.V. Kutuzov, O.V. Morozov, M.V. Teltsov,