Magnetic drug targeting of tumors situated in the cavity of the human body is difficult because the magnetic gradients decrease rapidly with the distance from the magnets. Here computer simulations are used to investigate different techniques to focus small MPs within the microvasculature of tumors. Non-invasive methods were found to have range <15Â cm whilst minimal invasive methods could be applied specifically to small tumors (<18Â mm).
Keywords
Related Topics
Physical Sciences and Engineering
Physics and Astronomy
Condensed Matter Physics
Authors
Ovidiu Rotariu, Norval J.C. Strachan,