Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
10715686 | Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment | 2011 | 6 Pages |
Abstract
The correct handling of statistical uncertainties is crucial especially when unfolding alpha spectra that contain a low number of counts or overlapping peaks from different nuclides. For this purpose, we have developed a new spectrum analysis software package called ADAM, which performs a full covariance calculus for alpha-particle emitting radionuclides. By analyzing a large number of simulated and measured spectra, the program was proved to give unbiased peak areas and statistically correct uncertainty limits. This applies regardless of the peak areas and the number of unknown parameters during the fitting. In addition, ADAM performs reliable deconvolution for multiplets, which opens the way for the determination of isotope ratios, such as 239Pu/240Pu.
Keywords
Related Topics
Physical Sciences and Engineering
Physics and Astronomy
Instrumentation
Authors
S. Ihantola, A. Pelikan, R. Pöllänen, H. Toivonen,