Abstract
Supermirror coating is a significant source of γ-radiation in neutron guide systems, which can cause serious problems at instruments by increasing the γ-background. This problem is more stringent in case of γ-sensitive signal detection, like PGAA or in-beam Mössbauer spectroscopy. Shielding possibilities close to the sample are limited, but guide shape has significant effect on the number of γ-photons produced in this region. To develop good γ-shielding and guide system we have to understand the source and transport of γ-radiation in neutron guides and surrounding shieldings. We have developed a program which integrate VITESS and MCNPX to calculate the γ-background. We compared the simulated γ-background and guide performance with measurements on real focusing guide configurations.
Keywords
Related Topics
Physical Sciences and Engineering
Physics and Astronomy
Instrumentation
Authors
A. Szakál, Sz. Czifrus, M. Markó, J. Füzi, L. Rosta, L. Cser,