Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
10715942 | Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment | 2009 | 18 Pages |
Abstract
This document describes results obtained from the Link alignment system data recorded during the Compact Muon Solenoid (CMS) Magnet Test. A brief description of the system is followed by a discussion of the detected relative displacements (from micrometres to centimetres) between detector elements and rotations of detector structures (from microradians to milliradians). Observed displacements are studied as functions of the magnetic field intensity. In addition, the reconstructed positions of active element sensors are compared to their positions as measured by photogrammetry and the reconstructed motions due to the magnetic field strength are described.
Related Topics
Physical Sciences and Engineering
Physics and Astronomy
Instrumentation
Authors
L.A. GarcÃa-Moral, G. Gómez, F.J. González-Sánchez, C. MartÃnez-Rivero, F. Matorras, T. Rodrigo, P. MartÃnez, L. Scodellaro, I. Vila, A.L. Virto, M. Sobrón, J. Alberdi, P. Arce, J.M. Barcala, E. Calvo, A. Ferrando, M.I. Josa, A. Molinero,